2 MobileView Junction Box
Publication 2727-IN010A-EN-P - May 2004
Junction Box Dimensions and Connections
K1
X1
X3
1
10
1
6
SHIELD
140 mm
(5.52 i
n)
165 mm (6.50 in)
70 mm
(2.76 i
n)
K1
17-pin female connector for connection cable
X1
Terminal block for power and control lines
X3
Terminal block for data lines
SHIELD
Cable shield clamp with connection surface for shield of data lines (not used
for strain-relief of the cable)
The Junction Box and the MobileView terminal meet the safety
class III in accordance with EN 61131-2 and EN 50178. When
connecting the MobileView terminal, make sure all voltages
connected to the terminal are safety low voltages and isolated
from the low voltage supply system by a safety transformer or
a similar safety component.
ATTENTION