Instruction Manual D2-8100

5

Step 5: Install the New
Contactor Bracket

Task

Description
Position and align the new contactor bracket onto the drive.

Re-use the four (4) M10 x 40 mm long screws and M10 conical washers from the existing
contactor mounting to mount the new contactor bracket.

A

B

(4) M10 x 40 mm Long Screw
(4) M10 Conical Washer From
Existing Contactor Mounting

See DETAIL A

17 mm
22 N-m (195 lb.-in.)

Torque

DETAIL A

New Contactor
Bracket
P/N 181777-C01

Min. 1/4 inch

Clearance

Between

Resistors and

New Bracket

A

B

Advertising