Step 5: install the new contactor bracket – Rockwell Automation Single Precharge Contactor Replacement Kit for LiquiFlo 2.0 AC Fr 3 Drive Ass'y User Manual
Page 5
Advertising
Instruction Manual D2-8100
5
Step 5: Install the New
Contactor Bracket
Task
Description
Position and align the new contactor bracket onto the drive.
Re-use the four (4) M10 x 40 mm long screws and M10 conical washers from the existing
contactor mounting to mount the new contactor bracket.
A
B
(4) M10 x 40 mm Long Screw
(4) M10 Conical Washer From
Existing Contactor Mounting
See DETAIL A
17 mm
22 N-m (195 lb.-in.)
Torque
DETAIL A
New Contactor
Bracket
P/N 181777-C01
Min. 1/4 inch
Clearance
Between
Resistors and
New Bracket
A
B
Advertising