Configuration – Rockwell Automation T7411F ICS Regent+Plus Monitored Digital input Modules, Field powered (Type F) User Manual

Page 15

Advertising
background image

Monitored Digital Input Modules, Type F (T7411F, T7418F)


P D - 7 0 2 7 M a r - 0 6

15

Configuration

Each monitored input module is configured using the
W

INTERPRET

I/O Configuration Editor. In the editor, you will

perform the steps described below to configure the input
module.

1) Set the Module Type:

Position the cursor on the module slot you wish to define.
Choose Set Module Type from the Edit Menu and select
either the T3411F or T3418F monitored digital input
module from the list.

2) Edit the Module Definition:

Choose Edit Module Definition from the Edit Menu. A
dialog box will open where you can define the input module
and point definitions. The figure below shows the dialog
for the T3418F input module.

Figure 9. Monitored Digital Input Module Definition.

3) Define the Input Module Fields and Thresholds:

With the cursor at the top of the list in the Module
Definition dialog shown in Figure 9, open the Line
Monitored Input Module dialog by pressing Enter or
double clicking on the “(Module)” selection. The dialog box
shown in Figure 10 will open.