9. Install the white motor thermostat leads (P1 and P2) to the thermostat connectors (9).

a. Slide the plastic sleeving over the connector and fasten the sleeving with electrical

tape.

b. Tape each lead individually, and then tape the two leads together.

10. Use wire ties to secure the encoder cable and thermostat leads to the motor frame.

Restrain all cables and wires to prevent contact or entanglement with rotating fan blades,
the motor, or moving parts on machine.

11. Slide the encoder cable into the slot on the fan cover, or rear cover, and then mount the

cover on the motor bracket.

12. Mount the encoder connector (10) to the top of the fan cover with four screws.

Additional Resources

For additional information on the HPK-Series encoders, refer to HPK-Series Motor Installation
Instructions, publication

HPK-IN001

.

You can view or download publications at

http://www.rockwellautomation.com/literature/

. To

order paper copies of technical documentation, contact your local Allen-Bradley distributor or
Rockwell Automation sales representative.

TIP

The encoder connector typically points in the same direction as the lead outlet on the motor
conduit box.

Use the

HPK-Series Motor Encoder - Later Version

diagram as a visual reference during removal

and installation of the encoder.