Chapter 3 Wiring Your Kinetix Safe Torque-off Drive

In this example, the Kinetix 6000 power rail contains three (single-wide) drives
using the safe torque-off feature and wired with one Kinetix 7000 drive. The
wiring headers and motion-allowed jumpers have been replaced as shown.

Figure 15 - Typical Kinetix 6000 to Kinetix 7000 Safe Torque-off Configuration

Cable connections to middle-drive headers (catalog number 2090-XNSM-M)
can be made to either connector. Input and output is not specified.

1202-C10

1202-C02 1202-C02

Safe Torque-off

Control Circuit Connections

Middle-drive Headers

(2090-XNSM-M)

Kinetix 6000

Drive

Last-drive Header

(2090-XNSM-T)

First-drive Wiring Header

(2090-XNSM-W)

Kinetix 7000

Drive

Drive-to-Drive Safe Torque-off Cables

IMPORTANT

Due to the current capacity limitation of the safe torque-off cable connectors,
multiple safe torque-off drive configurations must not exceed eight
Kinetix 6000 or Kinetix 7000 drive modules.