Rockwell Automation 2099-BMxx-S Kinetix Safe Torque-off Feature Safety Reference Manual User Manual

Page 28

Advertising
background image

28

Rockwell Automation Publication GMC-RM002F-EN-P - June 2013

Chapter 3 Wiring Your Kinetix Safe Torque-off Drive

Figure 17 - Single Drive (Stop Category 1) with Safety Relay Configuration

N.C.

N.C.

1

2

3

4

5

6

7

8

9

FDBK2+

FDBK2-

FDBK1+

FDBK1-

SAFETY ENABLE2+

SAFETY ENABLE -

SAFETY ENABLE1+

24V +

24V_COM

24V Com

24V +

Reset Out 12

Reset IN 21

1

2

Hardware Enable 24V+

Hardware Enable Input

Estop Out 12

Estop Out 22

Estop IN 11

Estop IN 21

Safe Torque-off

(STO) Connector

with

Wiring Header

I/O (IOD) Connector

Safe Torque-off

Demand

Reset PB

Safety Relay Rated for

SIL 3 per IEC 61508

Kinetix 6000 IAM/AM Module or

Kinetix 7000 Drive

Time Delay Contacts

24V+

24V Power Supply

24V Com

IMPORTANT

Pins STO-8 (internal 24V+ supply) and STO-9 (24V_COM) are used only by the
motion-allowed jumper to defeat the safe torque-off function. When the safe
torque-off function is in operation, the 24V supply must come from an external
source.