Rockwell Automation 440F MatGuard, 440F-C4000 Mat Controllers User Manual

Page 12

Advertising
background image

SENSOR MAT

Sensor mat conformity:

EN 1760-1, EN954 -1: CATEGORY 1, UL 508

Minimum weight of person with assured detection:

35Kg

Maximum detection zone:

100m

2

Maximum number of individual mats:

No limit (up to max 100m

2

)

Maximum total length of connection wires:

200m

Mass / m

2

(sensor mats):

24Kg

Environmental protection mats:

IP67

Mechanical life:

1 x 10

6

operations

Humidity:

0 - 100% RH

Sensor mat outer covering material:

Vinyl

Standard colour:

Yellow

Operating temperature range

-10°C to + 55°C

Storage temperature range

-40°C to +70°C

The system comprising of interconnecting sensor mats and control unit meets the requirements
of EN 954-1 category 3.

11

Control Unit

440F-C28013

Power supply

24V AC/DC or

110/230V selectable

Relay outputs

2 x independant volt free N/O safety contacts

1 x independant volt free N/C monitored contact

1 x volt free N/C auxilliary contact

1 x volt free N/O auxilliary contact

Safety inputs

8 x 4 wire mats with

molded Allen Bradley

connectors

Indicator LEDs

LED 1

Power

GREEN

LED 2

Manual reset mode

GREEN

LED 3

Auto reset mode

GREEN

LED 4

Machine enabled

GREEN

LED 5-12

Channel fault status

GREEN/RED

Terminals

Minus terminal

screws M2.5

mounted at 45°

to PCB

Note: for all other specifications and dimension details please refer to the 440F-C4000S control unit.