Rockwell Automation 440F MatGuard, 440F-C4000 Mat Controllers User Manual
Page 12

SENSOR MAT
Sensor mat conformity:
EN 1760-1, EN954 -1: CATEGORY 1, UL 508
Minimum weight of person with assured detection:
35Kg
Maximum detection zone:
100m
2
Maximum number of individual mats:
No limit (up to max 100m
2
)
Maximum total length of connection wires:
200m
Mass / m
2
(sensor mats):
24Kg
Environmental protection mats:
IP67
Mechanical life:
1 x 10
6
operations
Humidity:
0 - 100% RH
Sensor mat outer covering material:
Vinyl
Standard colour:
Yellow
Operating temperature range
-10°C to + 55°C
Storage temperature range
-40°C to +70°C
The system comprising of interconnecting sensor mats and control unit meets the requirements
of EN 954-1 category 3.
11
Control Unit
440F-C28013
Power supply
24V AC/DC or
110/230V selectable
Relay outputs
2 x independant volt free N/O safety contacts
1 x independant volt free N/C monitored contact
1 x volt free N/C auxilliary contact
1 x volt free N/O auxilliary contact
Safety inputs
8 x 4 wire mats with
molded Allen Bradley
connectors
Indicator LEDs
LED 1
Power
GREEN
LED 2
Manual reset mode
GREEN
LED 3
Auto reset mode
GREEN
LED 4
Machine enabled
GREEN
LED 5-12
Channel fault status
GREEN/RED
Terminals
Minus terminal
screws M2.5
mounted at 45°
to PCB
Note: for all other specifications and dimension details please refer to the 440F-C4000S control unit.