4-12
DeviceNet Communications Module
4.9
Resetting the Module
Changes to switch settings on some module parameters require
that you reset the module before the new settings take effect. You
can reset the module by cycling power to the drive or by using
Reset Module (6).
Set Reset Module (6) to 1 = Reset Module. See figure 4.12.
When you enter 1= Reset Module, the module will be immediately
reset. When you enter 2 = Set Defaults, the module will set all
module parameters to their factory-default settings. The value of
this parameter will be restored to 0 = Ready after the module is
reset.
!
ATTENTION: If the module is transmitting control
I/O to the drive, the drive may fault when you reset
the module. Determine how your drive will respond
before resetting a connected module. Failure to
observe these precautions could result in bodily
injury or damage to equipment.
Figure 4.12 – Reset Screen on an LCD OIM
Value
Description
0
Ready (Default)
1
Reset Module
2
Set Defaults
Reset Module
Parameter:
#
006
Ready
0
VALUE
LIMITS
SEL