Baumfolder BAUM20: Autoset Service Manual for Pile feed User Manual

Page 13

Advertising
background image

9.21 Press the “Deflect All” button

, so that the pan will go to its deflect position.

NOTE: FOLDER DRIVE MOTOR MUST BE OFF AT THIS TIME.

9.22 Repeat steps 9.11 through 9.20 for all the pans to be calibrated.

9.23 Turn off folder drive.

9.24 After everything is calibrated, Press the “Home” button to return to the main screen.


X. AUTOSET TROUBLESHOOTING GUIDE

10.1 Autoset computer screen not coming up.

A) Check power to machine.
B) Check main power switch.
C) Check F8 circuit breaker.
D) Check power switch on the computer.
E) Check voltage on the bottom of fuse block F20 & F21.
F) Check fuses F20 & F21.
G) Check power connector at the computer.

10.2 Autoset not working – whole machine.

A) Check Autoset power switch.
B) Check 10.1 items A thru F.

10.3 Autoset not working – one of the machine sections.

A) Check machine configuration and fold setting to assure that the connected configuration is

what is being called for by Autoset.

B) Check power supply for that section for the power indication light. Is it on? If on go to 10.3

C). If off go to 10.3 D).

C) If power supply indicator light is on, check F24 in parallel junction box, F28 in the 8-Page

junction box, F32 in the 16-Page junction box.

D) If power supply indicator light is off, check F22 & F23 in parallel junction box, F26 & F27

in the 8-Page junction box, F30 & F31 in 16-Page Junction box.

E) If fuses are good and 220 Vac is measured at the input of the power supply, replace the

power supply,

F) Is there 24Vdc between terminal blocks 203 and 202 in the parallel junction box, 303 and

302 in the 8-Page junction box, 403 and 402 in the 16-page box.

G) Check network fuse in the previous section. So if problem is in the 8-Page or stacker

connected to the 8-Page check F25 in the parallel junction box. Also check for 24Vdc
between terminal blocks 201 and 202 in parallel junction box.

H) Check Autoset wiring of junction box compared to schematic.


TP10512

TP10512

10 of 16

Advertising