Directional power sensor (dps), Figure 4 dps element orientation, Wideband power sensor (wps) – Bird Technologies 5000-EX User Manual
Page 23
 
Installation
11
Directional Power Sensor (DPS)
Connect the Bird DPS to the “Sensor” port on the DPM 
using the sensor cable provided.
Connect the DPS to the RF line so that the arrow on 
the sensor points towards the load. The arrow on the 
forward element should point towards the load. The 
arrow on the reflected element should point towards 
the transmitter. The forward element’s power rating 
must be 10x the reflected’s rating. Both elements must 
be either APM/DPM or 43 types, do not mix elements.
Wideband Power Sensor (WPS)
Connect the DPM port on the Bird WPS to the “Sen-
sor” port on the DPM using the sensor cable provided. 
Connect the WPS to the RF line so that the arrow on 
the sensor points towards the load.
Note:
The WPS is not compatible with the
Bird PCTool. Use the VPM software instead. 
Refer to the VPM Quickstart for connection 
instructions.
WARNING
RF voltage may be present in RF element socket.
Keep element in socket during operation.
Figure 4
DPS
Element
Orientation