Burst average power, Crest factor, Physical and environmental specifications – Bird Technologies 5000-EX User Manual
Page 47

Maintenance
35
Burst Average Power
Crest Factor
Complementatry Cumulative Distribution Function
(CCDF)
Physical and Environmental Specifications
RF Power Range
2 – 150 W average
Burst Width
1 µs – 50 ms
Repetition Rate, Min
15 Hz
Duty Cycle (D)
0.001 – 1
D = Burst Width / Period
Measurement Uncert.
± (6% of reading + 0.05/D W)
*
*
Above 35 °C or below 15 °C add 3%
RF Power Range
0.15 – 150 W
Measurement Uncert.
Linear sum of peak and average
power uncertainty
Measurement Range
0.1 – 100%
Measurement Uncert.
± 0.2%
Threshold Level Range
2 – 400 W
Level Set Accuracy
As peak power uncert. + 2%
Temp, Operating
–10 to +50 °C (+14 to +122 °F)
Temp, Storage
–40 to +80 °C (–40 to +176 °F)
Mechanical Shock and
Vibration
MIL-PRF-28800F class 3
Humidity, Max
95% (non-condensing)
Altitude, Max
15,000 ft. (4,500 m)
Dimensions, Nominal
4.75” x 4.6” x 1.3”
(121 x 117 x 33 mm)
Weight, Max
1.2 lb. (0.55 kg)