Bird Model 5000-EX Digital Power Meter
28
Bird 5010B Directional Power Sensor
Sensor Type
Bird Thruline directional two-
element line section.
Elements
APM/DPM or 43 series elements. 
Select two from the same series, 
with RFL power 1/10 of FWD power
Frequency Range
*
2 – 3600 MHz
Average Power Measurement, APM/DPM Elements, Forward 
or Reflected Direction
RF Power Range*
0.1 W to 1 kW
Uncertainty
†
± 5% of reading (95% c.l.)
Peak/Average
Ratio, Max
10 dB
Average Power Measurement, 43 Elements, FWD or RFL
RF Power Range*
0.1 W to 10 kW
Uncertainty
± 5% of full-scale power (95% c.l.)
Peak Power Measurement, 43 Elements, FWD only
Pulse Width, Min
2 – 25 MHz 15 µs
25 – 100 MHz1.5 µs
> 100 MHz
800 ns
Rep. Rate, Min
15 pps
Duty Cycle, Min
1 x 10
–4
Uncertainty
± 8% of full-scale peak envelope 