Combination Rolling Offset

Unlike a regular rolling offset, the entry and exit fittings for a

combination rolling offset are on different planes and therefore

have different fitting angles from each other.
Horizontal to Vertical
Find the pipe length, and entry and exit fitting angles for a

combination rolling offset with a vertical pipe exit, given a

Roll of 23”, Offset of 15”, and Advance of 29”. Use the box in

Diagram 1 to review the entry and exit pipe perspectives.

0’ -29”

ADVANCE

0’ - 15”
Offset

0’ - 23”
Roll

Unknown
Entry Fitting
Angle

Diagram 1

KEYSTROKE

DISPLAY

ALL CLEArEd

1. Solve for the pipe length and entry fitting angle

OFST 15 INCH

(Advance)

RUN 29 INCH

(Roll)

LNTH 39-15/16 INCH

FIT° 43.44°