Verify Communications

After powering up and binding the Gateway and its Nodes, verify all devices are communicating properly. Verify LED 1 is green. Until
communication is established with the Gateway, the Node’s LED 2 flashes red. When communication is established, the Node’s LED 1
flashes green.
A Node will not sample its inputs until it is communicating with the Gateway to which it is bound.

LED 1

LED 2

Gateway Status

Node Status

(green on)

Power ON

(green flashing)

RF Link OK

(red flashing)

(red flashing)

Device Error

Device Error

(yellow flashing)

Modbus Communication Active

(red flashing)

Modbus Communication Error

No radio link (when flashing
once every three seconds)

For Gateway and Ethernet Bridge systems, active Modbus communication refers to the communication between the Gateway and the
Ethernet Bridge. For GatewayPro systems, the Modbus communication LEDs refer to the communication internal to the Gateway Pro.
For Gateway only systems, the Modbus communication LEDs refer to the communication between the Gateway and its host system (if
applicable).
When testing the Gateway and Node, verify all radios and antennas are at least two meters apart or the communications may fail.

Specifications

Radio

Range

900 MHz: Up to 4.8 kilometers (3 miles) *
2.4 GHz: Up to 3.2 kilometers (2 miles) *

Transmit Power

900 MHz: 21 dBm conducted
2.4 GHz: 18 dBm conducted, less than or equal to 20
dBm EIRP

900 MHz Compliance (150 mW Radios)

FCC ID TGUDX80 - This device complies with FCC
Part 15, Subpart C, 15.247
IC: 7044A-DX8009

2.4 GHz Compliance

FCC ID UE300DX80-2400 - This device complies with
FCC Part 15, Subpart C, 15.247
ETSI/EN: In accordance with EN 300 328: V1.7.1
(2006-05)
IC: 7044A-DX8024

Spread Spectrum Technology

FHSS (Frequency Hopping Spread Spectrum)

Antenna Connection

Ext. Reverse Polarity SMA, 50 Ohms
Max Tightening Torque: 0.45 N·m (4 in·lbf)

Link Timeout

Gateway: Configurable
Node: Defined by Gateway

* With the 2 dB antenna that ships with the product. High-gain an-
tennas are available, but the range depends on the environment
and line of sight. To determine the range of your wireless network,
perform a Site Survey.

General

Power*

Requirements: +10 to 30V dc (For European applica-
tions: +10 to 24V dc, ± 10%). (See UL section below
for any applicable UL specifications)

Interface

Indicators: Two bi-color LEDs
Buttons: Two
Display: Six character LCD

SureCross DX80 Gateway with Discrete I/O

8

www.bannerengineering.com - tel: 763-544-3164

P/N 139075 rev. D

Advertising