Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Ez-screen, Grid, Ez-screen features

Advertising
background image

EZ-SCREEN

™

Grid

Instruction Manual

Printed in USA

09/01

P/N 68410

9714 10th Avenue North • Minneapolis, MN 55441

Phone: 763.544.3164 • http://www.bannerengineering.com

Email: [email protected]

Section Contents

Section 1

Introduction Overview . . . . . . . . . . . . . . . . . .Page 4

Section 2

System Components and Specifications . . . .Page 10

Section 3

Installation and Alignment . . . . . . . . . . . . . .Page 16

Section 4

System Operation . . . . . . . . . . . . . . . . . . . .Page 40

Section 5

Troubleshooting and Maintenance . . . . . . . .Page 45

Section 6

Periodic Checkout Procedures . . . . . . . . . . .Page 51

EZ-SCREEN Features

•

Non-contact safety device for perimeter and
access guarding from dangerous machinery

•

Diverse-redundant and self-checking design to
achieve control reliability and meet IEC 61496-1
type 4 requirements

•

Choose models with 2, 3, or 4 beams, beam
spacing from 300 to 584 mm (12" to 23")

•

Self-contained two-part system is optically
synchronized:

Needs no external controller
Needs no extra synchronization wire
Easy and economical to install

•

Operating range 0.8 to 20 m or 15 to 70 m
(2.6' to 65' or 49' to 230')

•

Selectable external device monitoring

•

Selectable trip or latch output

•

Fast 24 millisecond output response time for all
models

•

Easy-to-use removable terminal blocks or quick-
disconnect options speed and simplify wiring

•

Compact, robust housing

•

Multiple mounting options

•

Optional accessory interface module available
for ac or larger dc loads

•

Configuration settings accessible from the front,
with supplied tool. Sensor settings can be
changed while sensor remains mounted.

LISTED

US

Advertising
This manual is related to the following products: