Installation and Alignment

3.7.4 Remote Test Input

A pair of terminals is provided on the emitter terminal block (labeled TEST1 and
TEST2) for the connection of an external remote test switch (typically a normally
open contact held closed). This remote test input may be useful for EZ-SCREEN
Grid System setup and checkout procedures. Opening this switch “turns OFF” the
emitter, simulating an interruption of the light beams; all OSSD outputs will turn
OFF. The device used must be as specified in Section 2.5. (TEST1 and TEST2
terminals are factory jumpered.)

3.8 Preparing for System Operation

Perform the Commissioning Checkout, as described in Section 6.3.