EZ-SCREEN Grid System Specifications (continued)

page

14

Specifications

EZ-SCREEN Grid

Instruction Manual

Effective Aperture Angle
(EAA)

Meets Type 4 requirements per IEC 61496-2, Section 5.2.9
Short-range models: ± 2.5° @ 3 m
Long-range models: ± 2.5° @ 15 m

Shock and Vibration

EZ-SCREEN systems have passed vibration and shock tests according to IEC 61496-1 and -2.
This includes vibration (10 cycles) of 10-55 Hz at 0.35 mm (0.014") single amplitude
(0.70 mm peak-to-peak) and shock of 10 g for 16 milliseconds (6,000 cycles).

Enclosure

Size: See Figure 2-1
Materials: Extruded aluminum housings with yellow polyester powder finish and well-sealed,

rugged molded PBT end caps, acrylic lens cover

Rating: NEMA 4, 13; IEC IP65

Operating conditions

Temperature: 0° to +50° C (+32° to 122°F)
Max. Relative Humidity: 95% maximum relative humidity (non-condensing)

Status Indicators

7-Segment Diagnostic Indicators, Both Emitter and Receiver

Dash (–)

= System is OK

Error Codes

= See Section 5.1 for code definitions and recommended action

Scan code setting

= Appears during power-up or after scan code is changed.

(C1 or C2)

(Temporary indication; normal display resumes within a few
seconds.)

Emitter: One bi-color (red/green) Status indicator

Green steady

= RUN mode

Green single flashing = TEST mode
Red single flashing

= Lockout (see Section 5.1.2)

OFF

= No power to sensor

Receiver: Two system Status indicators, plus one bi-color (red/green) Beam Status indicator

for each beam

Yellow Reset Indicator

ON steady

= RUN mode

Double flashing

= Waiting for manual reset after power-up

Single flashing

= Waiting for manual latch reset

OFF

= No power to sensor or system is not ready for operation

Bi-Color (Red/Green) Status Indicator

Green steady

= Outputs ON

Red steady

= RUN mode, outputs OFF

Red single flashing

= Lockout (see Section 5.1.1)

OFF

= No power to sensor or system is not ready for operation

Bi-Color (Red/Green) Beam Status Indicators

Green steady

= Clear beam, strong signal

Green flickering

= Clear beam, weak signal

Red steady

= Beam blocked

OFF

= No power to sensor or no scanning

See Figure 1-5 for indicator locations.

Mounting Hardware

Emitter and receiver each are supplied with a pair of swivel end mounting brackets. Mounting
brackets are 8-gauge cold-rolled steel, black zinc finish.

Cables and Connections

Cables are user-supplied. Wiring terminals accommodate one 22 to 16 ga. wire or two wires
up to 18 ga.; Pg13.5 wiring chamber access port capacity varies, depending on cable gland
or strain relief fitting used. Supplied cable gland is for a cable diameter of 6 to 12 mm
(0.236" to 0.472").

Certifications

LISTED

US

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Other certifications pending; contact factory for further information