Installation and alignment, 3 mechanical installation considerations, 1 minimum separation distance (ds) – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 18

Advertising
background image

page

18

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Installation and Alignment

EZ-SCREEN Grid

Instruction Manual

3.3 Mechanical Installation Considerations

Two factors have the greatest influence on the mechanical installation of the
EZ-SCREEN System:

The required separation (safety) distance, and

The presence of hard guarding.

3.3.1 Minimum Separation Distance (Ds)

Minimum Separation (Safety) Distance (Ds) is the minimum distance required

between the light grid and the closest reachable hazard point. Separation distance
is calculated so that the EZ-SCREEN Grid System will send a stop signal to the
machine when an object or a person is detected (by blocking a sensing beam),
allowing the machine to come to a stop by the time the person can reach any
machine hazard point.

After the Ds is determined, record the calculated distance in Section 6.4 (step

2) of this manual, and/or on the Daily Checkout Card.

Figure 3-1. Separation distance

Ds

Ds

Ds

Hazard

Advertising
This manual is related to the following products: