System operation, 2 reset procedures 4.2.1 receiver resets, 2 emitter resets – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 41: 3 status indicators

Advertising
background image

page

41

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

System Operation

EZ-SCREEN Grid

Instruction Manual

4.2 Reset Procedures

4.2.1 Receiver Resets

The EZ-SCREEN Grid receiver has a RESET input, terminal 5, that allows the
System to be manually reset. To reset the receiver, close the Reset switch for 1/4
to 2 seconds, then open the Reset switch. (If Reset switch model MGA-KS0-1,
listed in Section 2, is used, close the switch by turning the key 1/4 turn
clockwise; open it by turning the key counterclockwise, back to its original
position.)

NOTE: Closing the Reset switch too long will cause the system to ignore the reset

request; the switch must be closed at least 1/4 second, but no longer than
2 seconds.

Receiver manual resets are needed in the following situations:

• When operating in Trip Output mode, manual resets are required only after a

system lockout (see Section 5 for causes).

• When the System is in Latch Output mode, a manual reset is required at

power-up, after each latch condition occurs, and after a system lockout.

4.2.2 Emitter Resets

In the rare occurrence that an emitter requires a reset, power the sensor down,
then power it up. Emitter resets are needed only if a lockout occurs.

4.3 Status Indicators

A variety of status indicators on both the emitter and the receiver are clearly
visible on each sensor’s front panel (see Figure 4-1).

Emitter: A single bi-color red/green Status indicator shows whether power is
applied, and whether the emitter is in Run mode, Test mode, or Lockout mode. A
7-segment diagnostic display indicates a specific error code when the emitter is
in Lockout mode. The 7-segment display also momentarily indicates the scan
code setting at power-up or when changed.

Operating

Mode

Required Event

Status Indicator

Diagnostic Display

Power-up

Apply Power

Red Single Flash

Scan code flash
3x (C1 or C2)

Run Mode

Passes Internal Tests

Green

Dash

Test Mode

Open Test Switch

Flashing Green

Dash

Lockout Mode

Internal/External Fault

Flashing Red

Displays Error
Code

*

Figure 4-2. Emitter status indicators and operation

* See Section 5.1 for a

description of error codes

Advertising
This manual is related to the following products: