Banner PT Remote Sensors User Manual
Page 2
!
WARNING
These photoelectric sensing devices do NOT include the self-checking redundant circuitry necessary to allow
their use in personnel safety applications. A sensor failure or malfunction can result in either an energized or a de-energized output
condition.
Never use these products as sensing devices for personnel protection. Their use as safety devices may create an unsafe condition
which could lead to serious injury or death.
Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA and ANSI machine
safety standards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, and they must NOT
be used as sensing devices for personnel protection.
LOGIC
OUTPUT
SPDT electro-
mechanical
relay, plus
NPN transistor
solid-state
switch
SPDT electro-
mechanical
relay (5 amp
contact rating)
MODEL
SUPPLY
VOLTAGE
CD3RA
CD3RB
CD5RA
CD5RB
ON/OFF
12
timing
functions
LOGIC
OUTPUT
ON/OFF
12
timing
functions
SPST solid-
state contact
for switching
ac loads up to
250V ac and
3/4 amp, plus
solid-state
contact for
switching
dc loads up to
30V dc and
up to 50mA.
105 to 130V ac, or
12 to 28V dc
210 to 250V ac, or
12 to 28V dc
105 to 130V ac, or
12 to 28V dc
210 to 250V ac, or
12 to 28V dc
CD3A
CD3B
CD5A
CD5B
MODEL
SUPPLY
VOLTAGE
105 to 130V ac, or
12 to 28V dc
210 to 250V ac, or
12 to 28V dc
105 to 130V ac, or
12 to 28V dc
210 to 250V ac, or
12 to 28V dc
Apertures
Rectangular and circular thread-on water-
tight apertures are available for SP12
sensors. Apertures are used to shape and
size the sensor's effective beam and to
protect the sensor's lens. Use of apertures
with these high-gain sensors makes it
possible to create very narrow, concentrated sensing beams for
demanding applications. Aperture Kit AP12SC includes three
round apertures with openings of .02", .04". and .10" diameter.
Aperture Kit AP12SR has three rectangular apertures .02", .04",
and .10" wide. Both include lens, o-rings, and thread-on housing.
Model SMB12MM Mounting Bracket
Model SMB12MM is a stainless steel mounting bracket for SP12
Series sensors. The sensor mounts to the bracket using the two jam
nuts supplied with the sensor. This rugged, slotted bracket allows
±
10 degrees of lateral movement. Bracket is 12-gauge stainless
steel. The bracket mounting holes accommodate #8 hardware.
RESPONSE SPEED: programmable for 1.5 or 15 milliseconds on/off
(15 millisecond setting produces maximum excess gain).
MAXIMUM SENSOR LEAD LENGTH: 100 feet (30 meters) each
for emitter and receiver. To avoid "cable crosstalk", always use
separate cable for emitter and receiver.
OPERATING TEMPERATURE RANGE: 0 to +50 degrees C (+32
to +122 degrees F).
1) Avoid running remote sensor cables in wireways together with
power-carrying conductors.
Wiring Guidelines
2) Avoid running remote sensor cables through areas of known
extreme electrical interference (electrical "noise").
3) When splicing, never combine emitter and receiver wires into a
common cable. (The result may be electrical "crosstalk" within the
cable, which causes a "lock-on" condition of the amplifier.)
CD Series modules combine power supply, modulated photoelec-
tric amplifier, timing logic (CD5 models), and a solid-state output
switch or electromechanical relay in a single compact module.
Only an 11-pin wiring socket (model RS-11) is needed to complete
the system.
The CD series contains models with either SPDT electromechani-
cal or SPST solid-state relay outputs and either with or without
programmable timing logic (models are listed in the tables at the
right). See product data sheet 03570 for further information.
One SP12 Series sensor pair may be connected to each module.
NOTE: to power the MAXI-AMP from a dc power supply, connect +12
to 28V dc at
≥
70mA to terminal #3 and dc common to terminal #1.
Make no connections to terminal #7 or #8 when powering a CD module
from a dc supply.
2
Specifications, MAXI-AMP™ CD Series Modules
Hookup to MAXI-AMP™ CD Series Modules