Sp12 series sensors, Sp12 sensor hookup to cd series maxi-amp ™ modules, 3) power for external devices (all models) – Banner PT Remote Sensors User Manual
Page 3: 2) logic level npn output (cd3 models), 1) hookup of sp12 series sensors (all models), Models with isolated solid-state contacts
3) Power for External Devices (all models)
External 10 to 30V dc devices such as self-
contained sensors may be connected be-
tween terminals #3 (+) and #1 (-) of any
CD series MAXI-AMP module. Termi-
nal #3 offers 40mA maximum. This is
sufficient to power most Banner self-con-
tained dc sensors.
As the example at the right illustrates, the
current sinking output of a self-contained
sensor powered by the MAXI-AMP may
be used as the input to the AUXILIARY
terminal of a CD5 module.
See Hookup Diagram #1 (above) for load and power connection information.
2) Logic Level NPN Output (CD3 models)
Typically, the CM5 module would
be programmed for the ONE-SHOT
or DELAYED ONE-SHOT logic
function. If the SP12 pair "sees" an
acceptable condition when the
SP300D senses the leading (or trail-
ing) edge of a product, the CD3 will
inhibit a reject pulse from occuring.
The AUXILIARY terminal (#9) of models CD3A, CD3B, CD3RA and
CD3RB modules offers a logic-level NPN (current sinking) output which may
be used as a fast-response solid-state inhibit signal to the AUXILIARY input
of MAXI-AMP CD5, CL5, CM5, or CR5 Series modules. This output may
also serve as an input to any MI-
CRO-AMP™, Plug Logic, or CL
Series logic module. In addition,
this output may interface to other dc
devices or circuits like counters,
rate meters, or programmable logic
controllers. Switching capacity is
20mA maximum at 12V dc max.
The example here shows the use of
SP12 Series sensors and a CD3 mod-
ule to provide inspection informa-
tion, with the SP300D functioning
as a product (GATE) sensor.
green
black
white
green
red
black
white
Gate
(Interrogate)
Data
(Inspection)
Inhibit
AC
Supply
CD3
models
8
7
6
5
4
9
10
11
1
2
3
AC
Supply
CM5
models
8
7
6
5
4
9
10
11
1
2
3
SP300D
SP12 Series Emitter
SP12 Series Receiver
blue
brown
NOTE: Black wire from
SE612
is not used
+15V dc
(#3)
GATE
(Interrogate)
CD5
models
Inhibit
White
green
blue
black
white
AC
Supply
Blue
(#1)
Brown
+15V dc @40mA
DATA
(Inspection)
SE612
8
7
6
5
4
9
10
11
1
2
3
brown
SP12 Series Emitter
SP12 Series Receiver
CD3RA
CD3RB
CD5RA
CD5RB
SPDT 5A
Relay
Output
AC
SUPPLY*
8
7
6
5
4
9
10
11
1
2
3
CD3A
CD3B
CD5A
CD5B
LED + (white)
LED - (green)
COMMON (black)
PT - (blue)
AUX
8
7
6
5
4
9
10
11
1
2
3
AC
SUPPLY*
PT + (brown)
AC Load
DC Load
Load Common
Models with isolated solid-state contacts
LED + (white)
LED - (green)
COMMON (black)
PT - (blue)
AUX
PT + (brown)
Emitter
Receiver
Emitter
Receiver
Models with electromechanical relay contacts
*105 to 130V ac or 210 to 250V ac, 50/60Hz, depending on model. To power the MAXI-AMP™ module from a dc supply, connect
+12 to 28V dc at
≥
70mA to terminal #3 and dc common to terminal #1. Make no connection to terminal #7 or #8.
SP12 Series sensors are especially designed for use with CD Series modules. The basic hookup is given here. Each MAXI-AMP™ CD Series module supports
use of one pair of SP12 Series sensors. CD5 Series module models also support use of a GATE or INHIBIT sensor at pin #9 (below, this page).
1) Hookup of SP12 Series Sensors (all models)
SP12 Series Sensors
SP12 Sensor Hookup to CD Series MAXI-AMP™ Modules