Watts R14-03-1WM User Manual
Page 6

A. SPECIFICATIONS
Productivity
(Gallons per day / Gallons per minute)
Maximum production based on standard membranes and feed water of 25°C, SDI < 3, 1000 ppm
TDS, and pH 8. Individual membrane productivity may vary (± 15%).
3600 / 2.5
Quality
(Typical Membrane Percent Rejection)
Based on membrane manufactures specifications, overall
system percent rejection may be less.
98 %
Recovery with reject recycle (adjustable)
50 %
Membrane Size
4 x 40
Number Of Membranes Per Vessel
1
Pressure Vessel Array
1:1
Number Of Membranes
2
Prefilter
(System ships with one 5 micron cartridge)
10" BB
Feed Water Connection
1" NPT
Product Water Connection
1/2" Tube
Reject Water Connection
1/2" Tube
Feed Water Required
(Max)
9 gpm
Feed Water Pressure
(Minimum)
10 psi
Drain Required
9 gpm
Electrical Requirement
115 VAC, 1-ph, 60 Hz (Other voltages available)
15 amps
Motor
(Horse Power)
1
Dimensions L x W x H
(Inches)
48” x 60” x 23”
Shipping Weight
(Estimated Pounds)
200
B. RO OVERVIEW
Reverse osmosis systems utilize semipermeable membrane elements to separate the feed
water into two streams. The pressurized feed water is separated into purified (product) water
and concentrate (reject) water. The impurities contained in the feed water are carried to drain
by the reject water.
RO Membrane
Feed Water Product Water
Reject Water