Bunn LCR-3 User Manual

Page 14

Advertising
background image

14

PROGRAMMING (Continued)

BibEMPTY LOCKOUT

NO EXIT YES

BREW LOCKOUT ?

NO EXIT YES

ENERGY SAVER MODE

NO EXIT YES

E-SAVER IDLE TIME

(-) 4 HRS (+)

E-SAVER TANK TEMP

NO EXIT 140

Select (YES) to enable

Select (YES) to enable

Select (ON) to enable

Use the (+) or (-) buttons to

adjust the Idle Time

Select OFF or 140° F (60°C)

Select YES to Lockout dispensing until the BIB is

replaced and the pump has been Primed. Default

is NO.

Select YES to Lockout dispensing until the hot

water tank is at READY Temp. Default is NO.

Select ON to enable Energy Saver Mode. Default

is OFF.

Enter the amount of inactive time before the

dispenser goes into Energy Saver Mode. Default

is 4 hrs. Maximum is 24 hrs.

Choose OFF to turn the tank heaters off completely

or 140°F (60°C) to hold hot water at 140°F (60°C)

during E-Saver Mode. Default is 140°F (60°C).

LCD DISPLAY

ACTION

DESCRIPTION

41129 071409