LCD DISPLAY

ACTION

DESCRIPTION

The following functions are for diagnostic and troubleshooting purposes and typically do not have to be adjusted.

Contact your local service agent for assistance before making changes to these functions.

PROGRAMMING (Continued)

CAL LEFT PUMP ?

LEFT

CAL LF PUMP VOL

(-) 58mL (+)

CAL MIDDLE PUMP ?

MIDDLE

CAL MID PUMP VOL

(-) 58mL (+)

CAL RIGHT PUMP ?

RIGHT

CAL RT PUMP VOL

(-) 58mL (+)

CAL HI WTR FLOW

PULL DISPENSER

CAL HI WTR VOL

(-) 1720mL (+)

XXX CAL -> XXX

(-) Tank Temp (+)

BIB EMPTY -> 600

(-) EXIT (+)

Place a 50 mL (#34843.1000)

graduated cylinder under the

dispense tip, then activate the

Left Pump

Use the (+) or (-) buttons to

enter volume collected

Place a 50 mL (#34843.1000)

graduated cylinder under the

dispense tip, then activate the

Middle Pump

Use the (+) or (-) buttons to

enter volume collected

Place a 50 mL (#34843.1000)

graduated cylinder under the

dispense tip, then activate the

Right Pump

Use the (+) or (-) buttons to

enter volume collected

Place a 64oz (2000mL)

container under the dispense

tip, then Press and Hold any

Dispense Switch

Use the (+) or (-) buttons to

enter volume collected

Use the (+) or (-) buttons to

adjust temperature reading

Use the (+) or (-) buttons to

adjust Empty BIB threshold

The Left Pump will dispense concentrate for 10

seconds, then shut off automatically. Collect and

measure the concentrate dispensed.

Enter the volume of concentrate measured from

the Left Pump in mL, (not Oz.)

The Middle Pump will dispense concentrate for

20 seconds, then shut off automatically. Collect

and measure the concentrate dispensed.

Enter the volume of concentrate measured from

the Middle Pump in mL, (not Oz.)

The Right Pump will dispense concentrate for 20

seconds, then shut off automatically. Collect and

measure the concentrate dispensed.

Enter the volume of concentrate measured from

the Right Pump in mL, (not Oz.)

The Dispenser will dispense hot water for 20

seconds, then shut off. Release Dispense Sw.

Collect and measure the water dispensed. Enter

the volume in mL. Default is 1720 mL

Adjust the display reading to match a calibrated

probe inserted next to the Tank Sensor, °F (°C)

Used to set the Conductance Threshold for the

Empty BIB warning. Default is 600