Commercial outdoor heater, Step 9 - testing procedure for propane, Testing procedure for natural gas – Garden Sun Heater HS-SS Commercial Square User Manual

Page 12: Do not use a flame for leak testing

Advertising
background image

12

COMMERCIAL OUTDOOR HEATER

STEP 9 - TESTING PROCEDURE FOR PROPANE

• Prepare a cup of very soapy water.

• Attach Regulator to your L.P. Tank. Tighten securely with a wrench or the

handwheel (if provided). Leave the L.P. Tank outside of the Cabinet for the testing

procedure.

• Open the valve on the L.P. Tank. Leave the Heater Valve in the “OFF” position.

• With a brush or sponge, apply the soap and water mixture liberally to the union

(junction) between the Regulator and the L.P. Tank, and the union between the

Regulator and the Valve Fitting.

• Any leaks will blow soap bubbles.

• Repair any and all leaks by tightening union with wrench.

• Once any and all leaks have been stopped, the heater is ready for use!

DO NOT USE A FLAME

FOR LEAK TESTING

TESTING PROCEDURE FOR NATURAL GAS

• Prepare a cup of very soapy water.

• Attach heater gas hose to gas supply line. Tighten securely with a wrench .

• Open the gas supply line valve. Leave the Heater Valve in the “OFF” position.

• With a brush or sponge, apply the soap and water mixture liberally to the union

between the supply line and heater valve. Any leaks will blow soap bubbles.

• Repair any and all leaks by tightening union with wrench.

• Once any and all leaks have been stopped, the heater is ready for use!

DO NOT USE A FLAME

FOR LEAK TESTING

Advertising