Trouble shooting, Commercial outdoor heater – Garden Sun Heater HS-SS Commercial Square User Manual

Page 19

Advertising
background image

19

TROUBLE SHOOTING

COMMERCIAL OUTDOOR HEATER

PROBLEM 3
Ignitor not lighting pilot

CAUSE A
Electrode not creating a sufficient enough spark to
ignite the gas
SOLUTION
CHECK SPARK GAP AND ELECTRODE
CONNECTIONS
1. Remove the hood and emitter by removing the (4)
screws that attach the emitter screen to the burner
plate.
2. Check the spark gap and adjust as illustrated.
3. Check all Electrode wire connections.

About 1/4” to 3/8” spark gap between

Electrode and Thermocouple

PROBLEM 3
Ignitor not lighting pilot

CAUSE B
Igniter AAA Battery not installed properly or without
power.
SOLUTION
CHECK BATTERY INSTALLATION OR USE NEW
BATTERY
1. See Page 13, Step 11 to install battery properly or
replace battery.
2. Check all igntier wires to make sure connected.
3. Trying lighting heater again while making sure gas is
flowing through the pilot.

Igniter Housing

AAA Battery

Spring

Contact Plate

Igniter Cap

Advertising