TROUBLE SHOOTING

COMMERCIAL OUTDOOR HEATER

PROBLEM 1

Burner won’t remain lit.

CAUSE A

Possible Leak

SOLUTION

Check all connections

1. Use liquid soap to find leaks. Pour over

connection between hose and regulator and

regulator to tank. If soap bubbles, leaks are present.

* With all Propane tanks in the US, if a leak is

present the tank will automatically shut-down.

2. Use teflon tape on all connections.

3. Tighten all connections.

4. Check for leaks again. NEVER USE AN OPEN

FLAME TO CHECK FOR LEAKS.

4 Re-light heater to test.

CAUSE B

Thermocouple may be too tight on valve.

* If thermocouple is too tight on valve, it will limit the

amount of millivolt electricity, which keeps the valve

flowing gas.

SOLUTION

Loosen Thermocouple

1.Remove cover opposite side the control knob with

phillips screwdriver.

2. With a wrench, loosen thermocouple connection

to valve (Copper lead with 1/4” flare fitting)

3. Hand tighten and slightly tighten with wrench. Do

NOT torque or over tighten.

4. Re-light heater to test.

CAUSE C

Tilt mechanism disconnected

*Your Heater has several safety features that

are connected via wires to the thermocouple.

Sometimes during movement or shipping, these may

become disconnected.

SOLUTION

Check inside of burner neck that all wires are

connected.

TEST WITH

GAS ON

AND REGULATOR

CONNECTED

TEST FOR

LEAKS HERE

FRONT

BACK

BACK

LOOSEN

THERMOCOUPLE