FOR YOUR SAFETY

READ BEFORE OPERATING

WARNING:

If you do not follow these instructions exactly, a fire or explosion may result causing

property damage, personal injury or loss of life.

A. This appliance operates with a Safety Pilot System. It is important that the pilot lights before the burner

can light.

B. BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor

because some gas is heavier (PROPANE) than air and will settle on the floor. (NATURAL GAS WILL

RISE)

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in

or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may

result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service

technician to inspect the appliance and to replace any part of the control system and any gas control

which has been under water.

E. Quick disconnects are not recommend because of possible gas leaking from connections.

CHOOSING A LOCATION

The heater may be installed on a combustible

floor surface. If the heater is installed near a

combustible wall or ceiling surface, the following

minimum clearances must be maintained:

24 in. from any ceiling surface, and 36 in. from

any wall on all sides.

This appliance is CSA Certified for outdoor installation

only in a well ventilated space. The installation of this

appliance must conform with local codes or, in the

absence of local codes, with the National Fuel Gas

Code, ANSI Z223.1-Latest Edition. It must not be used

in a building, garage, or any enclosed area or structure.

The ground surface used for installation must be firm

and level, and allow adequate ventilation around the

unit (a minimum of 36 in. clear per side). At no time

should any part of the L.P. cylinder enclosure be

blocked off.

24" FROM ANY
CEILING SURFACE

36" FROM
ANY WALL
ON ALL SIDES