AR/GE/FE/U 80/80X Installation Manual 

11 

580­00519 rev. D 

from the radome and rotate the radome so the drain hole is 
at the bottom. Be careful not to contaminate, damage or 
smudge the shiny coating of the antenna surface or 
feedhorn and make sure the gasket is evenly seated when 
re­attaching the radome cover. 

1.  Attach the upper pole mount to the antenna 

mounting plate. 

Confirm that the mount is centered as shown. 

Tighten bolts securely. 

Figure 3.5­1:  Upper pole mount attached to antenna 

mounting plate 

2.  Attach the lower pole mount and azimuth fine 

adjust as shown. 

Hardware: Flat washer, bushing (inside eye), 
flat washer, lock washer, bolt. 

Figure 3.5­2: Azimuth fine adjust assembly