AR/GE/FE/U 80/80X Installation Manual 

29 

580­00519 rev. D 

Failure to ‘Disable’ the Installation Auto­Calibration option can 
trigger an inadvertent re­calibration of the system, under certain 
power failure conditions.
 

3.10.3  Forced Re­Calibration 

Option 1: Use the Auto­Cal function in the NMS ‘Maintenance screen. This function will store the 
calibration values in non­volatile memory. 

Option 2:  Enable “installation auto calibration” in the NMS and ‘Apply Settings'. Disconnect the 
DC power and fiber optic cables from the radio. Power up the radio while the fiber is still 
disconnected. The Auto Calibration will start as soon as the fiber optic cable is reconnected to the 
radio terminal. 

When a radio is power cycled with the fiber connected to network equipment, the radio will use the 
calibration values stored in non­volatile memory from the last successful auto­calibration process 
even if the enable Auto­Cal setting being set to ‘Enable’. The radio link will come up immediately. 

When a radio has “Installation Auto Calibration” disabled, the radio will use the calibration values 
stored in non­volatile memory from the last successful auto­calibration process, regardless of the 
fiber interface connected to network equipment or not. 

Should moving the link to a new location or re­alignment of the 
link become necessary, the link must be recalibrated per the auto­ 
calibration procedure described in Section 3.10.