Qual & rsl test cable, 11 qual & rsl test cable – BridgeWave AR80 User Manual

Page 35

Advertising
background image

AR/GE/FE/U 80/80X Installation Manual 

30 

580­00519 rev. D 

3.11 QUAL & RSL Test Cable 

The alignment procedure is optimized through the use of the provided test cable.  This test cable is 
designed for use with a digital voltmeter (not provided) to read the Link Quality and Receive Signal 
Level (RSL) voltage generated by the radio’s receiver. See Figure 3.11­1. 

Figure 3.11­1: 

Supplied test cable for measuring Link Quality and Receive Signal Level voltages 

1.  To read the RSL value of the radio, insert GND (ground) and RSL banana plugs into the 

voltmeter. Note the RSL voltage. The voltage may be fluctuating; in this case, note the maximum 
value seen. 

2.  To read the Link Quality value of the radio, insert GND (ground) and QUAL banana plugs into 

the voltmeter. Note the Link Quality voltage. After the radios have performed an auto calibration 
the quality voltage should read 3.0­3.3VDC if the link is aligned on the main antenna beam and 
there are no obstructions (i.e., trees, buildings, etc…) in the path, the link distance is within the 
operating parameters of the radio (see Section 2.4 above), and it is not raining heavily.