Operational precautions, For sales/service, contact the following – IDX i200 User Manual

Page 4

Advertising
background image



OPERATIONAL PRECAUTIONS

1.

During charging the unit will get a little warm, this is normal.

2.

Do not rest any object on the unit, or block the ventilation holes during operation.

3.

Only use approved Nickel Cadmium and Nickel Metal Hydride batteries; do not use
faulty batteries or those with incorrect specifications.

4.

Other batteries besides 12V/13.2V NP/BP (1Ah~7Ah) may be charged with the
appropriate adapter, contact IDX for details.

5.

Do not expose the unit to direct sunlight, use in well-ventilated place.

6.

For longer battery life it is recommended to fully discharge once for every 8 charge
cycles for NiCd. (30 for NiMH)

7.

If the unit’s power fails to come on, check the fuse. If necessary, replace with spare
fuse provided.

8.

For repair or service: do not open the unit, please contact the factory offices or
authorized distributors.


FOR SALES/SERVICE, CONTACT THE FOLLOWING

IDX System Technology

IDX System Technology

Main Office/Service Department

Sales Development Office

1602 Lockness Place

19 Spear Road, Suite 203

Torrance, CA 90501

Ramsey, NJ 07446

Tel +1-310-891-2800

Tel +1-201-236-2103

Fax +1-310-891-3600

Fax +1-201-236-2131

SPECIFICATIONS


Applicable batteries NP-23dx, NP-1dx, NP-H50, NP-H50dx

BP-95dx or equivalent
(Batteries in the range: 12~13.2v 1~7Ahr)

Weight:………………....………………………………. 2.5lbs.(1.2kg)
Dimensions…..……………………………3.12”(W) x 6.24”(H) x 2.0”(D)

150mm(W) x 75mm(H) x 190mm(D)

Conditioning Charge current………………..…………….……..250mA
Quick Charge Current…………………….…….…………....…...1.85A
Discharge Current……..………………….…….………2.5A (@ 12.5V)
Discharge Cutoff……………….……………….……..….……....10.8V
Trickle Charge Current………….………….………..….…….…..30mA
Input Voltage...……………….…...AC100~240V (50/60Hz) Automatic
Charge Control System………..……...…….Full Digital Microprocessor
Negative Delta Voltage (-∆V

)

Advertising