Configuring Height for a Cone Bottom Tank
The
Pr 5 function enables you to enter the cone height for tanks that have a conical base. This may be required if you are
unable to mount the sensor at the center of the tank, or if the cone is causing false echoes and consequently faulty
measurements. The entered cone height value can be from a minimum of 000.000 (the default value) up to a maximum of
half the tank height value.
NOTE: An Err. 1 message is displayed if the cone height (h) is more than halt the Tank Height (H) value.
Press / Action
Display
Description
Configuring Height for a Cone Bottom Tank
program
Displays the default value (shown) or the last
entered value.
and
Use to enter the cone height value
Press ENT to select the value you entered from
the previous step.