OIL LEVEL CONTROLLERS WITH

–9

(Universal adapter),

-

10

(Slotted universal adapter),

-12

(Pole mounted adapter) AND –

FS OPTIONS

•

Set the controller so that the centerline of the sight window corresponds to the desired oil level in the crankcase.

•

Mount the controller close to the crankcase and connect the hose from the ¾” outlet located on the controller to the crankcase.
NOTE: The outlet port on the oil level controller must be located below the oil level in the crankcase.

•

An equalizing line must be used between the controller and crankcase in order to equalize the pressure. The tubing must be a
minimum of 1/2” I.D. and must be kept under 2 feet. DO NOT loop this line. It must be trap free and self draining, with a
downward pitch flow by gravity.

OIL LEVEL CONTROLLER WITH

–11

AND

–11-FS

OPTION (for Mechanical Lubricators): See Figure 3

OIL LEVEL CONTROLLER WITH

–14 AND –14 –FS

OPTION (White Compressor)

•

Remove the triangular blind flange located on the compressor and mount the controller assembly in its place.

• Drill holes in the lubricator housing as shown, and mount

the controller with the inlet located on the top side using the
seal washers and mounting bolts provided.

• Place the seal washers between the controller and the

lubricator housing.

Figure 3

Figure 2: Typical Mount of –9 Adapter