OIL LEVEL CONTROLLER WITH

–17

(Waukesha VHP Engines F2895, F3251, F5108, L5790 & L7042),

-18

(-17 w/ meter),

-27

(for newer Waukesha engines same as –17),

–37

(Waukesha P9390),

-38

(same as –37 w/ meter),

-47

(Waukesha VGF L36 and P 48

Engines) and –FS OPTIONS

•

Remove the cast aluminum inspection door from the engine. Remove the clamp bar from the old door.

•

For –17, -18, -37, -38 install the o-ring into the groove of the Kenco door and replace the clamp bar on the back side of the door
using the 5/8” bolts and the stat-o-seals supplied by Kenco.

•

For –27, install the o-ring into the groove of the Kenco door and replace the clamp bar on the back side of the door using the
7/16” bolts and the stat-o-seals supplied by Kenco.

•

For –47, mount the inspection door with the bolts, seal washers, and gasket provided.

•

For –17, -27, -37, -38, place the controller assembly into the inspection port of the engine and tighten the center bolt(s) down.

•

Install the equalizing line between the controller cover plate and the door (Tubing and connectors supplied by Kenco).

•

Place the controller assembly into the inspection port of the engine and tighten the center bolt(s) down.

•

Install oil inlet line into the controller oil valve or the meter inlet port.

•

NOTE: For the –18 model, refer to the additional instructions supplied with the 1618 Kenco Low Flow meter.

Figure 4: -Door Assembly for –17, -18, -27, -37, -38, -47

OIL LEVEL CONTROLLER WITH

-24

(Ariel Compressor JGB, JGE, JGH, JGK, JGR, JGT, JGV, & JGW) and

-48

(Ariel compressor JGC & JGD) AND –FS OPTIONS

•

Remove the sight glass located on the crankcase and replace it with the oil controller assembly using the mounting bolts and
gasket supplied with the unit.