ïì

I&O manual

WARNING

This type of installation requires that the supply air to the applian-
ce(s) be of a sufficient amount to support all of the appliance(s) in
the area. Operation of a mechanical exhaust, such as an exhaust
fan, kitchen ventilation system, clothes dryer or fireplace may cre-
ate conditions requiring special attention to avoid unsatisfactory
operation of gas appliances. A venting problem or a lack of supp-
ly air will result in a hazardous condition, which can cause the ap-
pliance to soot and generate dangerous levels of CARBON MINO-
XIDE, which can lead to serious injury, property damage and I or
death.

An «²½±²º·²»¼ -°¿½» is not less than 50 cu.ft (1.42m

3

) per 1,000Btu/hr

(0.2928 kW) input rating for all of the appliances installed in that area.
Rooms communicating directly with the space containing the appliances
through openings not furnished with doors, are considered a part of the
unconfined space.

In unconfined spaces (see definition below) in buildings, infiltration may
be adequate to provide air for combustion ventilation and dilution of flue
gases. However, in buildings of tight construction (for example, weather
stripping, heavily insulated, caulked, vapor barrier, etc.), additional air
may need to be provided using the methods described in “An confined
space” section.

An ½±²º·²»¼ -°¿½» is an area with less than 50 cu . ft (1.42m

3

) per 1,000

Btu/hr (0.2928 kW) input rating for all of the appliances installed in that
area. The following must be considered to obtain proper air for combus-
tion and ventilation in confined spaces.

Fig. 20 , “Combustion Air Inducer” shows the furnace as it is shipped
from the factory. To convert to a horizontal or downflow position,
remove the four screws that secure the inducer assembly and rotate 90
being careful not to damage the gasket. Reinstall screws. Remove cap
from appropriate vent outlet location on the cabinet cut insulation in
cabinet to same size as the hole provided and reinstall cap in the hole in
the top panel.

Fig . 20

Combustion Air Inducer

Mounting Screw (Remove)

Flue Transition
(Do Not Remove)

Fig. 22 Outside and Ambient Combustion Air

Gable
Vent

Gas
Vent

Soffit
Vent

Ventilated

Attic

Top Above
Insulation

Optional
Inlet (a)

Outlet
Air (a)

Ventilated

Crawl Space

Gas
Water
Heater

Soffit
Vent

Gas
Water
Heater

Inlet
Air (a)

Inlet
Air (b)

Gas
Vent

Outlet
Air (a)

Outlet
Air (b)

Inlet
Air (a)

Inlet
Air (b)

Gas
Water
Heater

Ventilated

Attic

Top Above
Insulation

Gable
Vent

Gas
Vent

In downflow applications, do not block the combustion air inlet.
The furnace must be installed on a coil cabinet or subbase to
allow combustionair to enter the burner compartment.

IMPORTANT

й КЫТМ НЗНМЫУ

йтп К»²¬ Э±²²»½¬·±²-

ЭЯМЫЩСОЗ п у млр Ът УЯИт КЫТМ МЫУРт

йто К»²¬·²¹

йтн К»²¬·²¹ Ч²¬± Я² Ы¨·-¬·²¹ Э¸·³²»§

М¸» º«®²¿½» -¸¿´´ ¾» ½±²²»½¬»¼ ¬± ¿ ¬§°» Þ ª»²¬ ½±²²»½¬±®ф М¸» º«®²¿½» -¸¿´´ ²±¬
¾» ½±²²»½¬»¼ ¬± ¿ ½¸·³²»§ º´«» -»®ª·²¹ ¿ -»°¿®¿¬» ¿°°´·¿²½» ¼»-·¹²»¼ ¬± ¾«®²
-±´·¼ º«»´т Н·²¹´»у©¿´´ ª»²¬ °·°» ·- ²±¬ ¿´´±©»¼ò

The venting system must be installed in accordance with Section 5.3
Air for combustion and Ventilation, of the National Fuel Gas Code
Z223.1/NFPA 54 (latest edition), or Sections 7.2, 7.3 or 7.4 of CSA
B149.1, National Gas and Propane Codes (latest edition) or applicable
provisions of the local building code and these instructions.

It is recommended that the appliance is installed in a location where the
space temperature is 32 °F( 0 °C) or higher. If the appliance is installed
in a location where the temperature is below 32 °F (0 °C) , the combustion
byproducts could condense causing damage to the appliance heat
exchanger.

This appliance may be common vented with another gas appliance for
residential installations as allowed by the codes and standards listed in
these instructions.

Category I venting consists of vertically venting one or more appliances
in B-vent or B-vent connectors. Type B-vent system extends in a gen-
eral vertical direction and does not contain offsets exceeding 45° .
A vent system having not more than one 60° offset is permitted.

This furnace may not be connected to any masonry chimney. However,
an existing masonry chimney may be used on as a chase through which
the metal vent pipe passes.

Fig. 21: Combustion Airflow Path Through The Furnace Casing to
the Burner Box

Combustion Air

90

90

йтмтп Я³¾·»²¬ Э±³¾«-¬·±² Я·® Н«°°´§

йтм Я·® Ъ±® Э±³¾«-¬·±² ¿²¼ К»²¬·´¿¬·±²

This type installation will draw the air required for combustion from
within the space surrounding the appliance and from areas or rooms
adjacent to the space surrounding the appliance. This may be from
within the space in a non-confined location or it may be brought into
the furnace area rom outdoors through permanent openings or ducts.
A single, roperly sized pipe from the furnace vent connector to the
outdoors must be provided. For upflow models combustion air is
brought into the furnace through the unit top panel opening.