Troubleshooting System Noise

AC grounding becomes critical when connecting high-performance audio components.

When you mix and match high-performance audio components, each with its own ground

potential, a low frequency hum may occur in one or both loudspeakers. This often occurs

when introducing a new component into a system.
If this happens when you place the Evolution e Series amplifier into your system, follow

these simple troubleshooting steps.

Note

During these steps, the back panel power breaker switch remains in the on position.

1.

Check that all input and output connections are of sound construction.

2.

With the amplifier in stand-by mode, remove the interconnect cables, then turn the

amplifier on. If the hum disappears, turn the amplifier into stand-by mode again, and

reinsert one of the interconnect cables. Turn the amplifier back on. Repeat this process

for each cable.

3.

If the hum reappears with one or both interconnect cables reinserted, the cable needs

to be checked.

4.

If the interconnect cables are sound, you may be experiencing a ground loop. Please

contact your authorized Krell dealer, distributor, or Krell for suggestions on how to

eliminate the ground loop.