La Cornue CornuFé 1908 - 36 User Manual
Page 46
Installation and User Guide CornuFé 1908 - 36" - USA / Can
08NOTINSTALFE8/USA-1
Oven Light
MAINTENANCE
44
If the range is to be used above 5,000ft (1,500m) the burner orifices must be changed. This
conversion must be performed by a qualified gas installer.
Read the instructions before converting this appliance.
Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead
to prosecution.
When servicing or replacing gas-carrying components disconnect from gas before commencing
operation.
Use the correct orifices for high altitude given by La Cornue service only for your appliance.
When you have completed the changes, check the appliance is gas sound.
CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
Do not use re-conditioned or unauthorized gas controls.
Save the orifices removed from the appliance for future use.
Check operation of all the burners.
After conversion the installation must comply with the relevant regulations and also the local
electricity supply company requirements.
The light is located on the side at the top of the oven; it is
automatically switched on when the oven door is opened.
Please note: disconnect your stove before interfering
with the light to prevent any risk of an electrical shock
and to allow the appliance to cool down (if necessary).
Remove the protection glass and then unscrew the
damaged light.
Refit a new light and the protection glass.
Technical characteristics of the light:
- 25W
- 230V - 240V
- 300°C
- E14 base
5. R
EPLACING THE OVEN LIGHT
4. C
ONVERTING FOR
H
IGH
A
LTITUDE