970 User Guide

v. 2.10

Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.

54

Se

tup Menu Op

tions

#

Parameter Name

Description

Options

2

Timecode Mode

Sets the running mode for the internal timecode

generator and/or the method which the 970 receives

SMPTE timecode.

• Off

» Freerun
• Freerun Auto Mute
• Record Run
• 24h Run
• 24h Run Auto Mute
• Ext TC (LTC)
• Ext TC (LTC Halt)

3

Frame Rate

The frame rate of timecode stamped to .wav files.

• 23.976
• 24
• 25

» 29.97
• 29.97 DF
• 30
• 30 DF

4

Auto-Record Hold Off

Sets the duration that a valid timecode signal has to

be recognized by the 970 before generating a new

take when using external timecode to trigger record-

ing (When [Remote Control - Rec Start/Stop]

is set to Timecode).

» 0 sec
(numeric 0-8)

5

Jam Received TC

Opens a dialog that displays incoming timecode

value in realtime (RxTC), incoming userbits (UB),

transmitting/internal (Ambient® Lockit) timecode value

(GENTC), and transmitting/internal userbits (UB).

• Push Control knob to jam inter-

nal timecode to incoming (RxTC)

timecode.
• Push MENU Button to back out.

6

Jam time Of Day

Sets the internal timecode clock to the current time

of day.

7

Set Generator TC

Sets the Ambient® Lockit timecode generator value in

HH:MM:SS.FF format.

» 00:00:00.00
(Timecode value)

8

UBits Format

Sets the four-field format for the UBits Generator to

the default, which is user definable fields, or so that

the first three fields are automatically populated with

numerical values based on the system date.
When set to MM:DD:YY:UU or DD:MM:YY:UU, the

system will populate the first three fields, so those

fields will appear grayed out in the Set Generator

UBits menu option, leaving only the last field (UU) to

be customized daily by the user.

» UU:UU:UU:UU
• MM:DD:YY:UU
• DD:MM:YY:UU

9

Set Generator UBits

Sets userbits of the Ambient® Lockit timecode

generator.

» 00 00 00 00
(Hex: 00-FF for each slot)

10

File Start TC Offset

Sets the offset of the beginning timecode stamp of

recorded files. Useful when there is a constant offset

between camera and 970 recorded files. The applied

offset does not affect timecode output of the 970.

» 0

(numeric -10 to +10)

Remote Control

#

Parameter Name

Description

Options

1

RS422

Enable or disable RS422 capability

• On

» Off

2

RS422 Interface Device ID

Set the DeviceID communicated to attached RS422

controllers.

» Sony BVW75
• Sound Devices

3

Rec Start/Stop

Enable or disable automatic recording with the pres-

ence of running timecode at the timecode input.

» Off
• Timecode

Advertising