MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL

!
!
!
!
! (ignore signal until
!
!X2 minimum cycle time)
!
11 +-I I----I I-------------------------------------------------[PLS M2
]+
!SENSB T40
PLSB !
!
!
!
!
!
!
!M11 Y1
!
14 +-I I--------------------------------------------------------------(
)--+
!ON A !
PUMPA !
! ! (min 150ms cycle)
K15 !
! +--------------------------------------------------------
(T40)-!
!
!
!M12 Y2
!
16 +-I I--------------------------------------------------------------(
)--+
!ON B !
PUMPB !
! ! (min 150ms cycle)
K15 !
! +--------------------------------------------------------
(T41)-!
!
!
!M1
!
18 +-I I-+------------------------------------------------------[SET
M11 ]+
!PLSA ! ON A !
! !
!
! !
!
! !
!
! !
!
! +------------------------------------------------------[RST
M12 ]+