MAXIM 50E/U PUMP OPERATION / MAINTENANCE MANUAL

PAGE 3

1

INSTALLATION

1.1 UNPACKING

After unpacking, the pump should be checked for any damage that may have
occurred during shipment. Damage should be reported to the carrier
immediately.

The following items should be included within the shipping container:

Qty

Item

Description

1

M50E/U

Maxim 50E/U Pump

1

MM50E/U

Operation/Maintenance Manual

2

DP-C-12

End-of-Stroke Probe (E Model only)

1

98002986

Fiber Optic Cable Cutter

1.2 UTILITIES / HOOK-UP

It is recommended that the pump be positioned within 15° from level to maintain
self-priming ability and pumping efficiency. Allow sufficient room for tubing
connectors. The pump mounts on a quick-change base for easy installation.

The pump has dual exhaust locations on the backside of the base. The exhaust
locations require 1/2” (12mm) minimum clearance behind the control base. Care
should be taken to elevate the pump whenever possible to help prevent flooding
when the pump is located in a wet bench plenum. For remote exhaust
connection see Section 1.5.

Air Inlet:

1/4” FNPT (3/8” Dia. [8mm] supply tube minimum).

Fluid Ports: Inlet/Outlet Fluid Fittings and Surge Suppressor require torqueing

during pump installation. See Section 2 for hook- up diagram and
torque values.

Air Supply:

20-80 psig (1.4

– 5.5 bar) clean dry air or nitrogen (see

Performance Charts, Section 3.1).