!M2
!
21 +-I I-+------------------------------------------------------[SET
M12 ]+
!PLSB ! ON
B !
! !
!
! !
!
! !
!

! +------------------------------------------------------[RST
M11 ]+
! ON
A !
!
!
!
!
!
!
!X0
!
24 +-I/I-+------------------------------------------------------[RST
M11 ]+
!CTRL ! ON
A !
! !
!
! !
!
! !
!
! !
!
! +------------------------------------------------------[RST
M12 ]+
! ON
B !
!
!
!
!
!
!
27 +------------------------------------------------------------------
[END ]+

4.10.c Combination End-Of-Stoke & Oscillator Reset