Appendix 1: input wiring requirements – Tweco Merlin 6000 Plasma Cutting CE Slave Power Supply User Manual

Page 35

Advertising
background image

Manual 0-2603

A-1

APPENDIX

APPENDIX 1: INPUT WIRING REQUIREMENTS

NOTES

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.

Cable conductor temperature used is 167° F (75° C).

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER

use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.

In p u t

P o w er In p u t

C u r r en t

S u g g ested S iz es (S ee N o t e)

V o lt ag e

F r eq .

3- P h

3- P h

F u se (A m p s)

W ir e ( A W G ) W ir e ( C an ad a) W ir e ( m m 2)

( V o lt s)

( H z )

( kV A )

( A m p s)

3- P h

3- P h

3- P h

3- P h

380

50/60

34

51

60

6

6

14

415

50/60

34

47

60

8

6

9

Li ne V ol tages w i th S ugges ted C i r c ui t P rotec ti on and W i r e S i z es

B as e d on N ati onal E l ec tr i c C ode and C anadi an E l ec tr i c al C ode

Advertising