Tweco Merlin 6000 Plasma Cutting CE Slave Power Supply User Manual

Page 39

Advertising
background image

Manual 0-2603

A-5

APPENDIX

3

LOGIC CONTROL BOARD

19

9

24

11

18

8

22

12

K2

SWITCH

RECOGNITION

START/STOP (CNC)

D8

START

INDICATOR

CONTACTOR

CONTROL

W

CONTACTOR

D9

J3-9

PWM

ENABLE

CONTACTOR DISABLE

(Only after main con-

tactor initially closes)

SENSE BRIDGE

VOLTAGE

<60VDC

TP1

TP4

To disable
this circuit for troubleshooting
short test points together.

HF AND PILOT

CONTACTOR

CSR Indicator

D10

15 VDC SUPPLY

2

1

28 VAC

CENTER TAP

TORCH VOLTAGE/23

CSR (from Current

Control Board)

TS3

TS1

TS2

ALL PC BOARD INPUTS

ACTIVE LOW EXCEPT

J1-24 AND J1-21.

21

22

OVER-CURRENT SHUTDOWN

(From Switching Control)

REFERENCES J1 CONNECTOR

REFERENCES J3 CONNECTOR

A-01534

D7

RUN

TS4

TS5

W-ON

APPENDIX 5-A: LADDER DIAGRAM - 15 vdc

(Rev AE or Earlier Logic Control PC Board)