INSTALLATION PROCEDURES

C. Optional SC-10 or SC11 Standoff Control

Cable

For mechanized systems, the Standoff Control automati-
cally finds height and maintains torch standoff with a high
speed torch lifter motor. The unit consists of a remote
operator's control, torch lifter motor, and all cables re-
quired for installation. It is ordered and shipped sepa-
rately. Refer to the SC-10 or SC11 Standoff Control In-
struction Manual for more information.

Depending on the Standoff Control to be used connect the
cable per one of the following:

• Standoff Control SC10 used with the Remote Control

RC6010

Connect the internal ribbon cable to the Remote Con-
trol RC6010. Refer to the Standoff Control Instruction
Manual for more details.

• Standoff SC11 only

The standoff control remote cable connects to the re-
ceptacle marked REMOTE CONTROL (J15) on the rear
panel of the Power Supply.

A-01766

Cable From

Standoff Control

REMOTE

CONTROL J15

Connector

Figure 3-16 Standoff Control Interface Connection

D. Optional High-Flow Water Shield Cable

The High Flow Water Shield surrounds the main cutting arc
with a spray of water to reduce arc glare, noise, and fumes. Use
of the water shield device reduces the system’s overall cutting
capacity. Refer to the High-Flow Water Shield Instruction
Manual for more information.

1. Connect the high flow water shield interface cable to

the receptacle marked HFWS J48 on the rear panel of
the Power Supply. The receptacle is 115VAC.

A-01768

High Flow Water Shield

Interface Cable

HFWS J48

Connector

Rotate Clockwise

To Lock

Figure 3-17 High Flow Water Shield Interface

Connection

2. Rotate the plug clockwise to lock the plug to the recep-

tacle.

3. To shut off the high flow water shield remove the inter-

face cable or disconnect power to the High Flow Wa-
ter Shield (HFWS) accessory.