G. Set Operating Pressure

1.

Place the Power Supply RUN / Rapid Auto Restart / SET switch to the SET (down) position. Gas will flow.

Art # A-03577

A

40

60

20

80

1

2

2.

Adjust gas pressure per the settings chart.

Leads

Length

SL100

(Hand Torch or

Machine Torch)

Up to 25'

(7.6 m)

70 psi

4.8 bar

Over 25'

(7.6 m)

75 psi

5.2 bar

CutMaster 101

Gas Pressure Settings

Art #A-03793

70 - 75 psi /
4.5 - 5.2 bar

Pressure Control Knob /
Bouton De Contrôle