OPERATION
4-4
Manual 0-2852
G. Set Operating Pressure
1.
Place the Power Supply RUN / Rapid Auto Restart / SET switch to the SET (down) position. Gas will flow.
Art # A-03577
A
40
60
20
80
1
2
2.
Adjust gas pressure per the settings chart.
Leads
Length
SL100
(Hand Torch or
Machine Torch)
Up to 25'
(7.6 m)
70 psi
4.8 bar
Over 25'
(7.6 m)
75 psi
5.2 bar
CutMaster 101
Gas Pressure Settings
Art #A-03793
70 - 75 psi /
4.5 - 5.2 bar
Pressure Control Knob /
Bouton De Contrôle
de Pression