Tweco CutMaster 101 User Manual

Page 39

Advertising
background image

Manual 0-2852

5-7

SERVICE

6. Unit internal fuse blown or loose

a. If blown, double-check input voltage and replace fuse per Section 5.04-C. If fuse blows again, return unit to

an authorized service center.

7. Actual input voltage does not correspond to voltage of unit

a. Verify that the input line voltage is correct. Refer to Section 2, Input Wiring Requirements.

8 . Faulty components in unit

a. Return for repair or have qualified technician repair per Service Manual.

B. Gas flows continuously when power is turned on, AC indicator

flashes

1. Torch switch is activated (closed) before user turns power on.

a. Release torch switch.

2. Faulty torch switch

a. Check torch switch for continuity. Replace if necessary.

C. Gas flows continuously; Torch will not pilot when torch switch is activated; AC indicator

ON

1. System is in SET mode

a. Change RUN / Rapid Auto Restart / SET switch to RUN (up).

D. No gas flow; RUN / Rapid Auto Restart / SET switch in SET position; Fans operate; AC indicator

ON;

GAS indicator

OFF

1. Gas not connected

a. Check gas connections.

2. Gas pressure too low for power supply operation

a. Adjust gas pressure per torch manual.

3. Faulty components in unit

a. Return for repair or have qualified technician repair.

E. Torch will not pilot; gas flows; AC indicator

ON, GAS

, TEMP , and DC

indicators OFF

1. Gas pressure is below power supply minimum requirement.

a. Adjust pressure to 60 - 75 psi / 4.1 - 5.2 bar.

F. Torch will not pilot; gas flows; AC

and Gas indicators

ON; DC

and TEMP

indicators OFF

1. Gas pressure is below torch minimum requirement (Minimum pressure for power supply operation is lower than mini-

mum required for torch operation.)

a. Adjust gas pressure per torch manual.

Advertising