3.03 Primary Input Power Connections

CAUTION

Check your power source for correct voltage before plugging in or connecting the unit. The primary power source,
fuse, and any extension cords used must conform to local electrical code and the recommended circuit protection
and wiring requirements as specified in Section 2.

Power Cord

This power supply includes an input power cord suitable for 230 VAC, 20 Amp, Single - Phase input

power.

Connect the input power cord as follows:

1. Check the power source for correct voltage before plugging in the unit.

2. Connect the input power cable (or close the main disconnect switch) to supply power to the system.

3.04 Gas Connections

A. Connecting Gas Supply to Unit

The connection is the same for compressed air or high pressure gas cylinders. Refer to subsection 3.4-C

if an optional air line filter is to be installed.

1. Connect the gas line to the inlet port. The illustration shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do Not
use Teflon tape as a thread sealer, as small particles of the tape may break off and block the small gas passages in
the torch.

A-07926

Min. 1/4 inch
6.4 mm

Gas Connection to Inlet Port

Advertising