INSTALLATION

3-4

Manual 0-5074

D. Using High Pressure Gas Cylinders

When using high pressure gas cylinders as the gas supply:

1. Refer to the manufacturer’s specifications for installation and maintenance procedures for high pressure gas

regulators.

2. Examine the cylinder valves to be sure they are clean and free of oil, grease or any foreign material. Briefly open

each cylinder valve to blow out any dust which may be present.

3. The cylinder must be equipped with an adjustable high - pressure regulator capable of outlet pressures up to

100 psi (6.9 bar) maximum and flows of at least 300 scfh (141.5 lpm).

4. Connect gas supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at the high pressure gas cylinder regulator.

Supply hose must be at least 1/4 inch (6 mm) I.D.

For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do Not
use Teflon tape as a thread sealer, as small particles of the tape may break off and block the small gas passages in
the torch.

3.05 Torch Connections

If necessary, connect the torch to the Power Supply. Connect only the Thermal Dynamics model SL60

Torch to this power supply.

WARNING

Disconnect primary power at the source before connecting the torch.

1. Align the male connector (on the torch lead) with the female receptacle on the power supply.

Press the connector into the receptacle fully.

2. Turn the locking ring on the male connector fully clockwise until it clicks.

1

2

Art # A-07929

Connecting the Torch to the Power Supply

3. The system is ready for operation.