Cutmaster 12mm, 04 gas connections – Tweco CutMaster 12mm User Manual

Page 24

Advertising
background image

CUTMASTER 12mm

3-2

INSTALLATION

Manual 0-5076

8. Reinstall the Power Supply cover per instructions found

in section 5.

9. Connect the opposite end of individual wires to a cus-

tomer supplied plug or main disconnect.

10. Connect the input power cable (or close the main

disconnect switch) to supply power.

3.04 GAS CONNECTIONS

Connecting Gas Supply to Unit

The connection is the same for compressed air or high pressure

cylinders. Refer to the following two subsections if an optional

air line filter is to be installed.

1. Connect the air line to the inlet port. The illustration

shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting

threads, according to manufacturer's instructions.

Do not use Teflon tape as a thread sealer, as small

particles of the tape may break off and block the

small air passages in the torch.

Art # A-07943

Hose Clamp

Regulator/Filter

Assembly

Inlet Port

Gas Supply

Hose

1/4 NPT or ISO-R

to 1/4” (6mm) Fitting

Air Connection to Inlet Port

Installing Optional Single - Stage Air Filter

An optional filter kit is recommended for improved filtering with

compressed air, to keep moisture and debris out of the torch.

1. Attach the Single - Stage Filter Hose to the Inlet Port.

2. Attach the Filter Assembly to the filter hose.

3. Connect the air line to the Filter. The illustration shows

typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting

threads, according to the maker's instructions. Do

Not use Teflon tape as a thread sealer, as small

particles of the tape may break off and block the

small air passages in the torch. Connect as follows:

Art # A-07944

Hose Clamp

1/4 NPT to 1/4"

(6mm) Fitting

Regulator/Filter

Assembly

Inlet Port

Gas Supply

Hose

Optional Single - Stage Filter Installation

Advertising